Residensi PR1MA A'Famosa 2 - Alor Gajah - Civil & Structural

active
Civil & StructuralAlor Gajah, Melaka, Malaysia

Submission deadline

30/11/2026 17:00

Site visit

Not scheduled

Contract duration

Site visit· 0 attendees signed up

No site visit time has been set. Propose a date and time and the property manager will be notified.

Tender details

Reference No.
JMB 16/2024
Category
Civil & Structural
Location
Alor Gajah, Melaka, Malaysia
Site visit
Not scheduled

Tender notes

Organisation: BADAN PENGURUSAN BERSAMA RESIDENSI PRIMA A'FAMOSA 2 JMB Registration Number: MPAG 501/039/02000 JMB 16/2024 Management Office Address: A-G-1, Jalan PR1MA 2/1, 78000 Alor Gajah, Melaka Contact Telephone: 011-55518577 Project Background • Defect Description: Severe horizontal crack/separation defect observed on ground-level structural/retaining element within ground floor parking area at Block D • Required Professional Qualification: Qualified Civil & Structural (C&S) Engineer Scope of Consultancy Services • Site Inspection & Condition Survey: Conduct detailed visual inspection, map crack patterns, and measure structural displacement • Geotechnical & Diagnostic Assessment: Specify and oversee any necessary subsurface/soil investigations (SI), non-destructive testing (NDT), or movement monitoring to evaluate ground settlement and structural integrity • Root Cause Analysis & Technical Report: Section header present but content not provided in excerpt Contact Details • Management Office Email: mopr1maafamosa2@gmail.com RFQ Issue Date: 19 November 2026 Property Address: Residensi PR1MA A'Famosa 2, Jalan PR1MA 2/1, 78000 Alor Gajah, Melaka Scope of Consultancy Services • Root Cause Analysis & Technical Report: Identify root cause and provide technical report (content details not provided in excerpt) Scope of Services • Root Cause Analysis: Determine whether the defects are attributable to construction non-compliance, inadequate workmanship, design deficiencies, material defects or other contributing factors • Permanent Rectification Proposal: Provide a detailed technical recommendation and method statement for permanent repairs, including possible roof slope modification, replacement of defective roofing components and improvement of the drainage system • Cost Estimation: Provide preliminary estimated costs for the proposed rectification works • Professional Technical Report: Submit a comprehensive assessment report supported by photographs, inspection findings, technical observations and recommended rectification measures. The consultant is requested to clearly state whether the observed roof condition complies with the original approved construction drawings and specifications. Any conclusion regarding construction non-compliance must be supported by technical findings and relevant evidence Submission Requirements • Itemized Fee Proposal: Broken down by stage: inspection/assessment and report, diagnostic testing/investigation, rectification design/proposal, and site supervision (if offered) • Professional Registration Details: e.g., BEM / PEPC registration in Malaysia, as applicable to the proposed scope of services • Estimated Timeline: For site inspection, diagnostic testing/investigation, and final report delivery • Past Project Experience: Brief profile of similar past projects involving structural defect assessments, ground settlement and/or roof leakage investigations • Specialist Testing Confirmation: Confirmation of whether any specialist testing or additional investigation is required, together with the associated estimated costs Project Description • Scope: Consultancy Services for Structural Defect Assessment and Rectification Proposal at Ground Floor Parking Area at Block D and Roof Leakage Investigation and Technical Assessment Contact Details • Contact Person: KAMAL KHAIRUDDIN BIN KASIR (Executive Building) • Phone / WhatsApp: 017-638 6352 Site Visit & Contact Information • Site Visit Arrangements: Joint site walkthrough can be arranged prior to quote submission. Interested consultants encouraged to inspect relevant locations including ground floor parking area at Block D and affected roof areas, subject to access arrangements. Submission • Submission Deadline: As Soon As Possible (ASAP) Structural Defect and Ground Settlement Assessment – Block D • Defect Location: Ground-level structural/retaining element within ground floor parking area of Block D • Required Assessment: Thorough technical assessment, ground/structural stability determination, root cause identification, and actionable rectification proposal Recurring Roof Leakage and Possible Construction Defects • Defect Location: Metal deck roofing system • Defect Timing: Particularly during periods of heavy rainfall • Affected Areas: Residential units • Suspected Cause: Non-compliance with original approved construction drawings and technical specifications, particularly in relation to roof gradient, drainage design and installation workmanship • Investigation Required: Investigate actual roof cause, verify compliance with original approved construction specifications, recommend permanent rectification solution 2.4. Remedial Method Statement & Specification • Deliverable: Design a complete rectification proposal including technical specifications, repair methodologies (e.g., underpinning, grouting, structural injection, drainage improvements), and preliminary cost estimates 2.5. Supervision & Certification (Optional/Phase 2) • Phase 2 Service: Provide site supervision during repair works and issue a final structural endorsement upon completion Structural Defect and Ground Settlement Assessment – Block D • Required Deliverable: Submit a comprehensive engineering report outlining the failure mechanism (e.g., differential settlement, soil movement, shear force, water pressure) and confirming structural safety Recurring Roof Leakage and Possible Construction Defects • Verification Task: The suspected non-compliance is to be technically assessed and verified by the appointed consultant Scope of Services - Part A • Site Inspection & Condition Survey: Conduct a detailed visual inspection, map crack patterns, and measure structural displacement Scope of Services - Part B • Construction Specification Verification: Review and verify the existing roof installation against the original approved construction drawings, technical specifications and relevant building requirements • Roof Slope Assessment: Assess the roof gradient and drainage design to determine whether insufficient slope or improper installation has contributed to water ponding and recurring leakage • Drainage System Assessment: Review and assess existing drainage outlets and supporting structures as part of roof inspection • Leakage Source Identification: Determine root causes of water ponding and recurring leakage through investigation of roof gradient, drainage design, and installation defects

Bill of Quantities

ItemDescriptionQuantityUnitNotes
1
Section 1
Site Inspection & Condition Survey
1lump sum—
2
Section 1
Geotechnical & Diagnostic Assessment
1lump sum—
3
Section 1
Root Cause Analysis & Technical Report
1lump sum—
4
Section 1
Remedial Method Statement & Specification
1lump sum—
5
Section 1
Supervision & Certification
1lump sum—
6
Section 1
Roof Inspection
1lump sum—
7
Section 1
Construction Specification Verification
1lump sum—
8
Section 1
Roof Slope Assessment
1lump sum—
9
Section 1
Water Ingress Investigation
1lump sum—

Tender documents

PR1MA A Famosa 2 Structural Defect 1.jpg

JPG

Download

PR1MA A Famosa 2 Structural Defect 2.jpg

JPG

Download

PR1MA A Famosa 2 Structural Defect 3.jpg

JPG

Download

PR1MA A Famosa 2 Structural Defect 4.jpg

JPG

Download

PR1MA A Famosa 2 Structural Defect 5.jpg

JPG

Download

Contractor?

Sign in to see the full Bill of Quantities and submit a quote.

Quote for This Tender

Is This Your Tender?

Take ownership to manage this tender and review contractor responses.

Own This Tender Now

Questions & answers

Sign in to ask

Only contractors invited to this tender can post in these threads, and everyone is shown anonymously.

No questions yet.